HEITAR VÖRUR
Plasma Gel Card Centrifuge 12/24 Blood Grouping Typeing ID Serological
| Forrit: | ●ABO blood type test test ●Rh blood group antigen test ●Irregular antibody screening ●Cross match |
●HDN detection ●Platelet antibody screening ●Platelet crossmatch |
| Hámarkshraði | 3500 snúninga á mínútu | |
| Max.RCF | 1554 xg | |
| Max.Capacity | 24 kort | |
| Passaðir snúningar | Disk card rotors | |
| Birta | LCD | |
| Model Number: | XK-12B | |
| vottun: | CE, ISO13485, ISO9001:2015 | |
| Ábyrgð í | 1 árs ábyrgð á allri vélinni, 3 ára ábyrgð á þjöppunni og 5 ára ábyrgð á mótornum. Ókeypis varahlutir og sendingarkostnaður innan ábyrgðar. | |
- Lýsing
- Video
- Tæknilegar Upplýsingar
- Rótorar og fylgihlutir
- Samkeppnisforskot
Micro column gel technology is extensively employed in blood serology, routine serum detection, red blood cell washing, microcolumn gel immunoassay experiments, and other applications due to its standardized operation and sensitive testing capabilities. The XK-12B blood gel card desktop low-speed centrifuge with a 12/24 card rotor meets the standard operation requirements for batch processing. The system features microcomputer control and automatic imbalance detection technology, ensuring easy operation and precise detection results. This instrument is essential for experimental hematology in hospitals and blood banks.
Principle for Blood Gel Card(ID-Card) Centrifuge
The principle behind the Blood Gel Card Centrifuge is based on the microcolumn gel immunoreaction, specifically the red blood cell agglutination test, also known as microcolumn gel hemagglutination assay (MGHA). Within the microcolumn gel tube, the red blood cells and their corresponding antibodies combine to form a clump of red blood cells. Through low-speed centrifugation, the clot is positioned either on the surface or within the gel, while the red blood cells that are not bound to the antibody settle at the bottom of the tube (the tip of the tube bottom).
Kostir
The advantages of Micro Column Gel Technology include its simplicity of operation, lack of washing and confirmation tests for negative results, which solves the problem of the Coombs test being difficult to routinely apply in clinical practice due to its complexity and time-consuming nature. It also promotes the incomplete antibody detection theory to become the clinical "gold standard". The system can process multiple specimens at once (12/24 cards), enabling the detection of a large number of clinical specimens. Additionally, it offers advantages such as accuracy, sensitivity, minimal specimen consumption, long-term storage of results, easy standardization, and safer operation.
Paternity Testing Method
The Paternity Testing Method involves the use of ABO blood type positive and negative type and RhD blood type test cards to detect human ABO and RhD antigens. The column agglutination method (microcolumn gel method) is a commonly used immunological method for blood group identification, in which red blood cell antigens and corresponding antibodies agglutinate in a microcolumn gel medium. This method is standardized and quantified, ensuring the accuracy of the results.
The following steps are involved in the process:
1.Blood sample collection (note: samples containing abnormally increased serum protein should be washed sufficiently before use).
2. Blood sample processing:
(i) Centrifuge the anticoagulated whole blood sample at 900~1000g centrifugal force for 5 minutes, the lower layer is the concentrated packed red blood cells with a concentration of about 80%. Carefully absorb the upper plasma in another test tube, which can be used directly in the experiment.
(ii) Dilute the packed red blood cells to be tested: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots. (iii) Dilute the red blood cells: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots.
3. Blood type card operation:
1) Mark the prepared micro-living gel reagent card.
2) Add the prepared red blood cell suspension to the first to fourth tubes respectively, and add the diluted inverted red blood cells to the fifth to sixth tubes.
3) Immediately centrifuge for 5 minutes (900rpm for 2 minutes, 1500rpm for 3 minutes) in a blood type card centrifuge, and take out the result of the naked eye judgment.
hönnun
● Microprocessor control with Brushless Motor. Accurate speed control.
● Easy operation. Colorful digital screen indicates all running parameters. Automatic lid -open alarm when the instrument is off.
● Professional programming design. No need for manual setting. Just run it.

Notendavænn
● Sjálfvirk lokslæsing og hald meðan á snúningi stendur.
● Sjálfgreiningarkerfi með hárstyrkri hólfahúð og verndandi.
● "Mute" einkaleyfi tækni, hæsta hraða aðgerð er minna en 50 desibel.
● Sjálfvirk rpm/rcf umbreyting.

Öryggi
● Framleitt samkvæmt alþjóðlegum öryggisreglum (td IEC 61010).
● Öryggi Rafmagns læsing loksins, hurðin getur ekki opnað þegar snúðurinn er í gangi og vélin mun ekki keyra þegar lokið er opið og villukóði birtist.
● Neyðarlosun á loki þegar rafmagnsleysi er (mjög gagnlegt við óvænt rafmagnsleysi).
● Öryggisvarnir eru gerðar gegn ofhraða til að tryggja öryggi manna og véla.

| Hraðasvið (rpm) | 0-3500rpm stillanleg | Hávaði (dBA) | ≦50 dB(A) |
| Hámarksgeta (ml) | 24 cards | Mál (mm) | 430*320*250mm(12 cards) 440*400*230mm(24 cards) |
| RCF svið (xg) | 0-1554xg stillanleg | Nettó þyngd | 13 KG (with 12 cards) 22KG (with 24 cards) |
| Rafmagn | AC220V, 50HZ, 5A, 60W | ||
| Nei | Liður | getu | Snúningshraði | Max.RCF | tími | Athugaðu |
|
NO.1
|
Pre-centrifuge program group | 12 kort | 3500r / mín | 1232xg | 1 mínútu | Program group can be set for different blood type cards. |
|
NO.2
|
Test program group | 12 kort | 900r / mín | 81xg | 2 mínútur | |
| 1500r / mín | 226xg | 3 mínútur | ||||
|
NO.1
|
Pre-centrifuge program group | 24 kort | 3500r / mín | 1554xg | 1 mínútu | |
|
NO.2
|
Test program group | 24 kort | 800r / mín | 81xg | 2 mínútur | |
| 1335r / mín | 226xg | 3 mínútur | ||||
![]() | ||||||
1.Professional skilvindu framleiðandi, samkeppnishæf verð.
2.ISO9001, ISO13485, CE, SFDA vottun, allar vélar gangast undir strangar gæðaprófanir og góðar umbúðir fyrir flutning.
3.Langtíma tækniaðstoð og fagleg þjónusta við viðskiptavini á hverju stigi vörusölu, afhendingu og reksturs. Mjög hæft og reyndur þjónustuteymi okkar veitir þér einstakan stuðning við kaupin alla ævi.
4.Við getum einnig boðið sérsniðnar lausnir fyrir sérstakar kröfur viðskiptavina.
5.Knúið með skilvirku teymi verkfræðinga sem studd er af margra ára reynslu á sínu sviði, tryggir fyrirtækið að hver einasta vara sem fer frá framleiðslueiningunni sé í hámarki í hvívetna.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ


















